A219 DRIVEFLEX® VFD 2kV RHW-2 with 3 Symmetrical Grounds
Part number | Description No. of conductors incl. ground | OD - Ø ca. mm | OD - Ø ca. inches | Weight Lbs/Mft | Copper Lbs/Mft |
---|---|---|---|---|---|
A2190103 | AWG 1 (840 strands) AWG8 (128 strands) 3C + 3PE | 37.1 | 1.460 | 1,676 | 1,125 |
A2190203 | AWG 2 (672 strands) AWG10 (80 strands) 3C + 3PE | 31.5 | 1.240 | 1,294 | 880 |
A2190603 | AWG 6 (266 strands) AWG12 (50 strands) 3C + 3PE | 26.3 | 1.035 | 804 | 422 |
A2191/003 | 1/0 (1064 strands) AWG8 (128 strands) 3C + 3PE | 39.4 | 1.551 | 1,957 | 1,355 |
A2192/003 | 2/0 (1344 strands) AWG8 (128 strands) 3C + 3PE | 42.4 | 1.669 | 2,294 | 1,628 |
A2190403 | AWG 4 (420 strands) AWG12 (50 strands) 3C + 3PE | 28.7 | 1.129 | 943 | 593 |
A2193/003 | 3/0 (1664 strands) AWG6 (206 strands) 3C + 3PE | 43.7 | 1.720 | 2,800 | 2,065 |
A2194/003 | 4/0 (2052 strands) AWG6 (206 strands) 3C + 3PE | 49.8 | 1.960 | 3,423 | 2,465 |
A21925003 | 250 MCM* (2432 strands) AWG6 (206 strands) 3C + 3PE | 54.9 | 2.161 | 3,997 | 2,862 |
A21935003 | 350 MCM* (3458 strands) AWG4 (322 strands) 3C + 3PE | 60.7 | 2.389 | 5,310 | 4,002 |
A21950003 | 500 MCM* (4864 strands) AWG4 (322 strands) 3C + 3PE | 67.6 | 2.661 | 6,928 | 5,402 |
A21975003 | 750MCM*/03C (7372 strands) AWG2/03C (672 strands) 3C + 3PE | 79.5 | 3.129 | 10,366 | 8,122 |
Voltage: | 2000V 90C TC-ER 2000V 90C Flexible VFD Servo Cable 1000V 90C WTTC | |
Temperature range: | -40°C - +90°C static | |
Bending radius min: | 7.5 x cable OD | |
Conductor marking: | Black with white numbers and three green/yellow ground | |
Approvals: | UL Type Flexible Motor Supply Cable, Flexible VFD Servo Cable up to 4/0, Meets NEC 336, 392 Class I & II Div. 2 and Class I Zone 2 per NEC 501, 502, 505 UL Types WTTC, TC-ER c(UL), CIC FT4, CE UL 1277, UL 2277 P-07-KA130021-MSHA CE, RoHS, REACH, TSCA *1000V WTTC, 2000V TC-ER only | |
Construction: | AWG conductor Class K flexible fine wire stranded tinned copper conductors for improved electrical characteristics and reduced oxidation Thermoset XLPE insulation, Wet/Dry RHW-2 (3C power + 3C Grounds/PEs) Shielded with foil tape, tinned copper braid with ≥80% optical coverage, and drain wire Oil resistant PVC jacket Black jacket similar to RAL 9005 | |
Oil resistance: | Oil Res II Specifications subject to change without prior notice |
Capacitance | Impedance | |||
---|---|---|---|---|
Part number | Mutual (pF/ft) | Ground (pF/ft) | Mutual (Ohms) | Ground (Ohms) |
A2190103 | 28 | 78 | 64 | 20 |
A2190203 | 28 | 85 | 60 | 19 |
A2190603 | 24 | 50 | 71 | 25 |
A2191/003 | 29 | 84 | 61 | 19 |
A2192/003 | 30 | 91 | 58 | 17 |
A2190403 | 26 | 74 | 66 | 22 |
A2193/003 | 31 | 98 | 56 | 16 |
A2194/003 | 33 | 107 | 53 | 15 |
A21925003 | 33 | 103 | 54 | 15 |
A21935003 | 34 | 113 | 51 | 14 |
A21950003 | 36 | 125 | 48 | 13 |
A21975003 | 36 | 134 | 47 | 12 |